Here a hand built refractory core had to be connected to an existing chimney of concrete brick. The chimney had an 8 inch diameter cast iron flu surrounded by vermiculite insulation. The only place to install a shut off damper was between the core and the chimney. Besides this being a limited space in which to install the damper, it was also the connection of the heater to the chimney.
![]() |
The chimney was opened up and a stainless steel section of 7 inch stainless pipe used to enter the existing cast iron flue of the chimney. |
![]() |
With limited space between the core and the facing, the 8x8 inch cast iron shut off damper had to be installed in a manner that would withstand regular operation for years. |
![]() |
The opening for the connection is spanned by a piece of quarter inch flat bar. The care in which the subsequent courses are layed will be crucial to the durability of the lintel and the sliding damper behind it. |
![]() |
The first course of the hearth bridges the rear manifold the whole of one corner resting upon the lintel. |